Maintenance, Overhauling & Pressure Testing of HALON 1301, HALON 2402, HALON 1211, CO2, FM 200 and CLEAN AGENT fire systems.
Sole Distributors for FIRE FITE brand of Fire Extinguishers which have also been approved by Director General of Shipping (MMD), the range of fire extinguishers also include Modular Stand Alone Self Fired Extinguishers,DCP,AFFF Foam Type, Clean Agent and Halon Fire Extinguishers.
We also stock and supply spares for Fire Hydrants and Fireman Alarm systems which include Deluge Valves, Projectors, IC Valves, Medium and High Velocity Sprayers, Jets, Nozzles and Ejectors.
Dry Powder ABC(Stored Pressure) :
Fire Fite ABC stored pressure fire extinguishers contains Mono Ammonium Phosphate based dry powder as per IS: 14609,These are useful fo fires in volving materials like oil, fats, solvents, gases, paints, vanish, electrical wiring and live machinery, Extinguish fire by blanketing displacement of air and decomposition of dry powder effects.
Carbon Dioxide (CO2) Fire Extinguishers :
Fire Fite CO2 type fire extinguishers are suitable for fires involving materials
like inflammable liquids, gaseous and electrical fires, oil spilages, etc. They are ideal to handle live delicate machinery flammable liquids and gases Extinguishing fires by blanketing dilution of oxygen and cooling effect involving high voltage electrical equipment. The fire extinguishers includes: seamless cylinder conforming to IS 7285 with ISI Mark and CCE Approval Valve conforming to IS 3224 with ISI Mark Squeeze grip valve also available.
Dry Chemical Powder Type Fire Extinguisher(DCP) :
Fire Fite dry powder type fie extinguishers are useful for fires involving
Materialslike oil,fats, solvents, gases, paint,vanish, electrical wiring and
live machinery Extinguish fire by blanketing displacement of air and
decomposition of dry powder effects, We also provide with Special ‘D’ Type
fire extinguishers(Dry Chemical Powder) with special powder and special
nozzle. Specifically suited for Metallic Fires.
Clean Agent Fire Extinguisher :
Fire Fite Clean agent fire extinguishers store agent as a liquid which turns to gas
when it hits the air. Clean agent extinguishers are effective on class A,B,
and C fires and will not conduct electricity back to the user. Clean agent
extinguishers act to extinguish a fire by cooling and something it(without thermal shock to delicate electronic equipment) Clean agent extinguishers the fire by interrupting the Chemical Reaction of the fire. Clean Agent is Primarily Suited for ‘B’ and ‘C’ classes of Fire But some large clean agent extinguishers can be used on class A,B and C fires.
These extinguishers have Zero global warming (or ozone depletion) potential . Some typical applications. Some typical applications include:
Computer Rooms/Server Rooms
Telecommunications Facilities
Clean Rooms
Data Storage Areas
Irreplaceable document and art storage rooms
Laboratories
Office (for Protection of sensitive electronic equipment)
Capacities Available:500gms,1kg,2kg,5kgs,10kgs welded cylinders as well s seamless cylinders are available
Modular Automatic Fire Extinguishers Clean Agent/Halon ABC:
-2 Kgs
-5Kgs
-10Kgs
-15Kgs
CAPACITIES AVAILABLE.
Water Type (Co2) Gas Catridge)Fire Extinguisher) :
Fire FiteWater Type (Gas Catridge)Fire Extinguishers are useful for fire
involving wood paper and similar materials , These are idea l for offices
schools threatres hospitals department stores, store rooms apartments hotels
and furniture Extinguishes fire by blanketing dilution of oxygen and
cooling effects.
FIRE PROTECTION SYSTEMS :
Carbon Dioxide :
Fire extinguishing system is designed to detect , isolate and extinguish fires. These are five basics components in high pressure carbon dioxide fire extinguishing system regardless of type; detectors, controls, cylinders piping and nozxles.
At the hazard specifically designed nozzles provide for the proper application of the carbon dioxide automatic detection causes the cylinders, to be released.
Carbon dioxide fire extinguishing system is used on a very wide variety of hazards where it is important to detect isolate and extinguish fires at the first of the flame.
One of the main applications for carbon dioxide systems is in process and machines where flammable liquids and vapours are present . Fire in these hazards spread so rapidly and become so hot that many times they cannot be approached let alone be extinguished with the usual portable equipment .A ‘built-in-system’ designed specifically for the hazard and operated automatically, assures immediate detection and very rapid extinguishment.
Carbon dioxide had many advantages as fire –extinguishing agent .It is odorless and non-toxic and A dry gas. It will ot conduct electricity cannot damage clothes or equipment nor contaminate liquids or food Carbon eliminates after blaze damage and mess, dissipating into the atmosphere without a trace.
FM 200 :
FM 200 systems are engineered to achieve minimum design concentration in 10seconds or less quickly extinguishing fires . stopping the fire in the early critical seconds can save millions of rupees worth of equipment lost production FM 200’smechsnism of extinguishing fires is active Its primary action is thoroughly & physically cooling the fire at th3e molecular level FM200 belongs to the same class of components used in refrigeration and as such is an efficient heat transfer agent FM 200 literally removes heat energy from the fire to the extent that the combustion reaction cannot sustain itself Additionally there is a chemical extinguishing action contributed by FM 200 Trace amount of free radical are released in afire ultimately inhibitant the chain reaction of combustion.
The extinguishing performance of FM 200 requires only a modest increase in agent storage cylinders compared to Halon 1301.FM200 saves expensive floor space for Productive use.
HYDRANT SYSTEM :
It is consist of fire pump set(main pump diesel engine booster pump) jockey pump control panel net work of pipe hydrant valves fire fighting hoses branch pipe with nozzle.
These systems are required for industries commercial residential hospitals and so on, we take pleasure in accomplishing fire safety through hydrant systems safety and timely and efficient project accomplishment.
SPRINKLER SYSTEM :
These systems mainly consist of main pump jockey pump control panel deluge valve net work of pipe sprinkler are mostly required for industries commercial residential hospitals schools etc
We have successfully installed in institutes such as Indian Education Society auditoriums etc.,
SPRAY SYSTEM :
Spray system are are available in two categories viz. High Velocity Water Spray (HVWS) and Medium Velocity water spray system(MVWS) It consists of pump & Motor Control Panel, Deluge Valve Net Work of pipe Spray Nozzles, Detector Line Electric/Pneumatic/Water These are installed in industries, Power plants, Gas plants and Transformers.
We have successfully accomplished Transformer safety in Bharat Forge Ltd. And our projects are running efficiently in various places.
FOAM SYSTEM :
It is consist of pump control panel network of pipe foam water monitors foam generators foam makers and foam pourers & inductors foam systems are highly suitable for oil and solvent industries